• Murphy EL150K1 Level Switch Quick View
    • Murphy EL150K1 Level Switch Quick View
    • Murphy EL150K1 Level Switch
    • The L150 Series Level Swichgage® instrument is a combination liquid level gage and low-limit switch; each unit includes: (1) a chamber with pivotal float (2) an indicating dial with pointer (3) a low-level contact. When properly installed and maintained, the float operates the pointer which, in turn, both indicates level during normal operation and closes a switching circuit if the level falls to the low-limit set point. For bigger quantities, please contact us to get a special quote. Technical Data
    • 190.72 (excl. VAT)
    • Add to cart
  • Murphy EL150EX Level Switch Quick View
  • Murphy LR857 Level Switch Quick View
  • Murphy LM2000 Level Switch Quick View
    • Murphy LM2000 Level Switch Quick View
    • Murphy LM2000 Level Switch
    • Murphy LM2000 model maintains the crankcase oil level of an engine, pump or compressor. Adjusted to the correct running-oil-level, the LM2000 will replenish oil as it is used. An integral, low-level switch will alarm and/or shutdown the equipment if supply oil is lost and the equipment continues to use oil. Replaced by FW Murphy LM500 Technical Data
    • Read more
  • Murphy L129 Level Switch Quick View
    • Murphy L129 Level Switch Quick View
    • Murphy L129 Level Switch
    • The L129 Series Lube Level Swichgage® instrument is a combination lube level indicating gage and adjustable low and high limit switches. It provides protection against low oil level or high level caused by overfill or fuel or water seepage into the crankcase. Technical Data
    • 245.33 (excl. VAT)
    • Add to cart
  • Murphy L129CK1 Level Switch Quick View
    • Murphy L129CK1 Level Switch Quick View
    • Murphy L129CK1 Level Switch
    • Murphy L129CK1 Level Switch The L129 Series Lube Level Swichgage® instrument is a combination lube level indicating gage and adjustable low and high limit switches. It provides protection against low oil level or high level caused by overfill or fuel or water seepage into the crankcase. The L129CK1 was designed for applications requiring a three-wire, above ground electrical circuit. It features ungrounded contacts and a conduit hub to protect electrical wiring. Options are available for both models. Check Lube Level Without Shutting Down. Use On Engines, Pumps, And Compressors. Technical Data
    • 289.50 (excl. VAT)
    • Add to cart
  • Murphy L971 Level Switch Quick View
    • Murphy L971 Level Switch Quick View
    • Murphy L971 Level Switch
    • The L971 Level Switch is designed for Ingersoll-Rand Type 30, Type 40 and ESH compressors, yet it can be adapted to fit other compressors that have an inspection plate extending below normal operating oil level. It installs with minimal downtime and has a two-year limited warranty. Durable Low Level Switches. Installs with Minimal Downtime Technical Data
    • Read more
  • Murphy L100 Level Switch Quick View
  • Murphy L120 Level Switch Quick View
  • Murphy L127/L128 Level Switch Quick View
  • Murphy LM300 Level Switch Quick View
    • Murphy LM300 Level Switch Quick View
    • Murphy LM300 Level Switch
    • The LM300 Series Level Maintainer automatically adds oil to the crankcase as needed to keep the lube level normal. Most models have built-in switches that will alarm and/or shut down the equipment if the makeup supply is depleted and engine oil level falls or if overfill conditions exist. The LM300 can be used in engines, compressors, pumps and coolers. The LM300 Series EX models (explosion-proof) are CSA certified for Class I, Division 1 Hazardous areas. Technical Data
    • Contact us to get an offer
  • Murphy DF Level Switch Quick View
    • Murphy DF Level Switch Quick View
    • Murphy DF Level Switch
    • Murphy DF Level Switch This simple level switch is highly reliable and can be worked into almost any new or existing system without major modification or special tools. DF755 and DF757 are suitable for atmospheric tanks in a non-hazardous area. The SPDT snap-switch for the DF755 is preset for a 4 in. (102 mm) differential in liquid level. The DF757 trip point is adjustable over a 108 in. (2743 mm) differential. Typical application is to start and stop electric driven pump(s) to maintain tank levels. It is also applicable to engine-driven pumps. Technical Data
    • Read more
  • Murphy BLSK1 Level Switch Quick View
  • Murphy LS200 Level Switch Quick View
    • Murphy LS200 Level Switch Quick View
    • Murphy LS200 Level Switch
    • Murphy LS200 Level Switch Designed for harsh gas compressor scrubber applications, the LS200 Series Liquid Level Switches feature a robust design that trips on rising liquid level only. With both electric and pneumatic models available, the instruments screw directly into the vessel or can be mounted via an external float chamber. The nickel-plated body provides enhanced corrosion protection while the 304 stainless steel float operates in 0.55 specific gravity and heavier fluids. Additional features include: Rated for 2000 psi (13.8 MPa) [138 bar] working pressure Listed for Class I, Div. 1, Grp. C & D locations Canadian registered Stainless steel models available for corrosive atmospheres   The LS200 Series replaces the FW Murphy Series L1200 Liquid Level Switches. The MSLS (Scrubber Level System) replaces the LS200 high-level shut-down switch with the MLS-020 magnetic level switch. Technical Data
    • Read more
  • Murphy DVU Dump Valve Quick View
  • FW Murphy LM500 Lube Level Maintainer Quick View
    • FW Murphy LM500 Lube Level Maintainer Quick View
    • FW Murphy LM500 Lube Level Maintainer
    • The FW Murphy LM500 model maintains the crankcase oil level of an engine, pump or compressor. Adjusted to the correct running oil level, the LM500 will replenish oil as it is used. The low level switch will alarm and/or shut down the equipment if the supply oil is lost and the equipment continues to use oil.Direct Mount (DM) capableEliminates under/overfill due to “human error”See oil level and condition without shutting downSimple installationAutomatically maintains lube levelLow level, 3-wire, snap-action switchPositive sealing Thumb-Valve™
    • 188.07 (excl. VAT)
    • Add to cart
  • FW Murphy LM500-TF Quick View
    • FW Murphy LM500-TF Quick View
    • FW Murphy LM500-TF
    • The LM500-TF model includes a test feature that confirms both the float and switch are operating correctly with a single press of the test button. Direct Mount (DM) capable Eliminates under/overfill due to “human error” See oil level and condition without shutting down Simple installation Automatically maintains lube level Low level, 3-wire, snap-action switch Positive sealing Thumb-Valve™
    • 212.00 (excl. VAT)
    • Add to cart
  • Murphy L1100 Level Switch Quick View
    • Murphy L1100 Level Switch Quick View
    • Murphy L1100 Level Switch
    • Replaced by LS200  These float operated level switches are available in electric and pneumatic models. They are primarily designed for high level applications but models are available for low level. Electric models are listed for Class I, Division 1, Groups C & D hazardous locations. Models are available in all stainless steel to NACE standard MR-01-75 for direct exposure to H2S service. These level switches have screw-in connections for direct installation or an optional external float chamber is available for the L1200 series high pressure versions. The high pressure versions of both L1100 and L1200 series are rated for 2000 psi (13,8 MPa) [138 bar] operating pressure. Designed for harsh gas compressor scrubber applications. More robust design. Technical Data
    • Read more
  • Murphy L1200 Level Switch Quick View
    • Murphy L1200 Level Switch Quick View
    • Murphy L1200 Level Switch
    • Murphy L1200 Level Switch Replaced by LS200  These float operated level switches are available in electric and pneumatic models. They are primarily designed for high level applications but models are available for low level. Electric models are listed for Class I, Division 1, Groups C & D hazardous locations. Models are available in all stainless steel to NACE standard MR-01-75 for direct exposure to H2S service. These level switches have screw-in connections for direct installation or an optional external float chamber is available for the L1200 series high pressure versions. The high pressure versions of both L1100 and L1200 series are rated for 2000 psi (13,8 MPa) [138 bar] operating pressure. Designed for harsh gas compressor scrubber applications. More robust design. Technical Data
    • Read more
  • Bubble Lens for Murphy Level Maintainer LM300 Series Quick View
  • Murphy Dump Valve DVU150 Quick View
    • Murphy Dump Valve DVU150 Quick View
    • Murphy Dump Valve DVU150
    • MURPHY DVU150 1800 PSI (12.4 MPa)The DVU Series are pneumatically controlled dump valves. The valves open and close automatically by pneumatic control from a Murphy L1200NDVOR or similar Murphy level controller and dump valve operator.The DVU series dump valves operate at 30–70 psi (207–483 kPa) [2.07–4.83 bar] and up to 2000 psi (13.8 MPa) [138 bar] vessel pressure (depending on the model).A key benefit of this design is a hex union that provides the ability to replace the seat without removing the valve from piping. Body Material: Electroless Nickel Plated 12L14 Carbon Steel. Internal Wetted Parts:Plug Seal: 90 Durometer UrethaneOther: 303 stainless steel; Electroless Nickel Plated 12L14 Carbon Steel. Technical Data
    • Read more
  • Murphy Dump Valve DVU175 Quick View
    • Murphy Dump Valve DVU175 Quick View
    • Murphy Dump Valve DVU175
    • MURPHY DVU175 1800 PSI (12.4 MPa)The DVU Series are pneumatically controlled dump valves. The valves open and close automatically by pneumatic control from a Murphy L1200NDVOR or similar Murphy level controller and dump valve operator.The DVU series dump valves operate at 30–70 psi (207–483 kPa) [2.07–4.83 bar] and up to 2000 psi (13.8 MPa) [138 bar] vessel pressure (depending on the model).A key benefit of this design is a hex union that provides the ability to replace the seat without removing the valve from piping. Body Material: Electroless Nickel Plated 12L14 Carbon Steel. Internal Wetted Parts:Plug Seal: 90 Durometer UrethaneOther: 303 stainless steel; Electroless Nickel Plated 12L14 Carbon Steel. Technical Data
    • Read more
  • Murphy Dump Valve DVU2105 Quick View
    • Murphy Dump Valve DVU2105 Quick View
    • Murphy Dump Valve DVU2105
    • MURPHY DVU2105 500 PSI (12.4 MPa) The DVU Series are pneumatically controlled dump valves. The valves open and close automatically by pneumatic control from a Murphy L1200NDVOR or similar Murphy level controller and dump valve operator.The DVU series dump valves operate at 30–70 psi (207–483 kPa) [2.07–4.83 bar] and up to 2000 psi (13.8 MPa) [138 bar] vessel pressure (depending on the model).A key benefit of this design is a hex union that provides the ability to replace the seat without removing the valve from piping. Body Material: Electroless Nickel Plated 12L14 Carbon Steel. Internal Wetted Parts:Plug Seal: 90 Durometer UrethaneOther: 303 stainless steel; Electroless Nickel Plated 12L14 Carbon Steel. Technical Data
    • Read more
  • Murphy Dump Valve DVU2115 Quick View
    • Murphy Dump Valve DVU2115 Quick View
    • Murphy Dump Valve DVU2115
    • MURPHY DVU2115 1500 PSI (10.3 MPa)The DVU Series are pneumatically controlled dump valves. The valves open and close automatically by pneumatic control from a Murphy L1200NDVOR or similar Murphy level controller and dump valve operator.The DVU series dump valves operate at 30–70 psi (207–483 kPa) [2.07–4.83 bar] and up to 2000 psi (13.8 MPa) [138 bar] vessel pressure (depending on the model).A key benefit of this design is a hex union that provides the ability to replace the seat without removing the valve from piping. Body Material: Electroless Nickel Plated 12L14 Carbon Steel. Internal Wetted Parts:Plug Seal: 90 Durometer UrethaneOther: 303 stainless steel; Electroless Nickel Plated 12L14 Carbon Steel. Technical Data
    • Read more
  • Murphy Dump Valve DVU2120 Quick View
    • Murphy Dump Valve DVU2120 Quick View
    • Murphy Dump Valve DVU2120
    • MURPHY DVU2120 2000 PSI (13.8 MPa)The DVU Series are pneumatically controlled dump valves. The valves open and close automatically by pneumatic control from a Murphy L1200NDVOR or similar Murphy level controller and dump valve operator.The DVU series dump valves operate at 30–70 psi (207–483 kPa) [2.07–4.83 bar] and up to 2000 psi (13.8 MPa) [138 bar] vessel pressure (depending on the model).A key benefit of this design is a hex union that provides the ability to replace the seat without removing the valve from piping. Body Material: Electroless Nickel Plated 12L14 Carbon Steel. Internal Wetted Parts:Plug Seal: 90 Durometer UrethaneOther: 303 stainless steel; Electroless Nickel Plated 12L14 Carbon Steel. Technical Data
    • Read more
  • Murphy Level Maintainer LM302 Quick View
    • Murphy Level Maintainer LM302 Quick View
    • Murphy Level Maintainer LM302
    • The LM302 Level Maintainer automatically adds oil to the crankcase as needed to keep the lube level normal. LM302 base model comes as a level maintainer with two switches for low and high level shutdown or alarm. Four wires, DPST, wired N.O. in normal operating ranges. Technical Data
    • Read more
  • Murphy Level Maintainer LM303 Quick View
    • Murphy Level Maintainer LM303 Quick View
    • Murphy Level Maintainer LM303
    • The LM303 Level Maintainer automatically adds oil to the crankcase as needed to keep the lube level normal. LM303 base model comes as a level maintainer with two switches for low and high level shutdown or alarm. Four wires, DPST, wired N.C. in normal operating ranges. Technical Data
    • Read more
  • Murphy Level Maintainer LM304 Quick View
    • Murphy Level Maintainer LM304 Quick View
    • Murphy Level Maintainer LM304
    • The LM304 Level Maintainer automatically adds oil to the crankcase as needed to keep the lube level normal. LM304 base model comes as a level maintainer with two switches. Alarm before shutdown on low level and shutdown on low-low level.Four wires, DPST, wired N.O. in normal operating ranges. Technical Data
    • Read more
  • Murphy Level Maintainer LM305 Quick View
    • Murphy Level Maintainer LM305 Quick View
    • Murphy Level Maintainer LM305
    • The LM305 Level Maintainer automatically adds oil to the crankcase as needed to keep the lube level normal. LM305 base model comes as a level maintainer with two switches. Alarm before shutdown on low level and shutdown on low-low level. Four wires, DPST, wired N.C. in normal operating ranges. Technical Data
    • Read more