Hotstart In-block Heater CUC-152FP for Cummins Engines complete with 2-wire w/ground 6’ (1.8m) HPN cord and plug. Application : Replaces 57.8mm core plug on right rear side of engine.
The LM301 Level Maintainer automatically adds oil to the crankcase as needed to keep the lube level normal. LM301 base model comes as a level maintainer with low switch contacts for low level shutdown or alarm. Four wires, SPDT. Technical Data
500W 240V 2.0A 1"NPT Oil Immersion HeaterOE650200-000 lube oil heater is installed within the engine's oil pan to maintain the warmth and viscosity of the oil when the engine is shut down. Cold oil tends to thicken, making it challenging to pump. By preheating the oil, it ensures smooth circulation to crucial engine wear points upon start-up. This proactive measure minimizes engine wear and facilitates smoother starts, ultimately extending the life of the battery.
Reliable spring starter for medium-sized diesel and gas engines. The Spring Starter Midi SDC011-1P offers battery-free starting—perfect for remote, off-grid, or emergency use. Compact, durable, and easy to install. Key Features: -No battery or wiring required -Rugged and maintenance-free -Ideal for engines up to mid-range capacity Technical Data
Reliable spring starter for medium-sized diesel and gas engines. The Spring Starter Midi SDC013-1P offers battery-free starting—perfect for remote, off-grid, or emergency use. Compact, durable, and easy to install. Key Features: -No battery or wiring required -Rugged and maintenance-free -Ideal for engines up to mid-range capacity Technical Data
Reliable spring starter for medium-sized diesel and gas engines. The Spring Starter Midi SDC014-1P offers battery-free starting—perfect for remote, off-grid, or emergency use. Compact, durable, and easy to install. Key Features: -No battery or wiring required -Rugged and maintenance-free -Ideal for engines up to mid-range capacity Technical Data
Reliable spring starter for medium-sized diesel and gas engines. The Spring Starter Midi SDC015-1P offers battery-free starting—perfect for remote, off-grid, or emergency use. Compact, durable, and easy to install. Key Features: -No battery or wiring required -Rugged and maintenance-free -Ideal for engines up to mid-range capacity Technical Data
Reliable spring starter for medium-sized diesel and gas engines. The Spring Starter Midi SDC016-1P offers battery-free starting—perfect for remote, off-grid, or emergency use. Compact, durable, and easy to install. Key Features: -No battery or wiring required -Rugged and maintenance-free -Ideal for engines up to mid-range capacity Technical Data
Adjustable/Fixed Thermostat. Light Housing. Assembled with a built-in thermostat and 1.3 mtr. power cord. Coolant Volumes up to 12 Liter. 2.1 Amps, 500W, Engine Displacement: 2.5L Technical Data
1000W, 240V, ON:27C, OFF: 38C Adjustable/Fixed Thermostat. Light Housing. Assembled with a built-in thermostat and 1.3 mtr. power cord. Coolant Volumes up to 12 Liter. Technical Data
TPS Model, Single Phase, Engine Displacement: 350CID 5.7L, 1000W, 4.2 Amps, 240 V, 38-49°C Adjustable/Fixed Thermostat. Light Housing. Assembled with a built-in thermostat and 1.3 mtr. power cord. Coolant Volumes up to 12 Liter. Technical Data
240V, 1500W, 6.3 Amps, On: 27°C, Off: 38°C Adjustable/Fixed Thermostat. Light Housing. Assembled with a built-in thermostat and 1.3 mtr. power cord. Coolant Volumes up to 12 Liter. Technical Data
TPS Model, Single Phase, Engine Displacement: 350 – 500CID, 5.7 – 8.2L, 1500W, 6.3 Amps, 240V, 38-49°C/ 100-120F Adjustable/Fixed Thermostat. Light Housing. Assembled with a built-in thermostat and 1.3 mtr. power cord. Coolant Volumes up to 12 Liter. Technical Data
Adjustable/Fixed Thermostat. Light Housing. Assembled with a built-in thermostat and 1.3 mtr. power cord. Coolant Volumes up to 12 Liter. Technical Data
Adjustable/Fixed Thermostat. Light Housing. Assembled with a built-in thermostat and 1.3 mtr. power cord. Coolant Volumes up to 12 Liter. Technical Data
Adjustable/Fixed Thermostat. Light Housing. Assembled with a built-in thermostat and 1.3 mtr. power cord. Coolant Volumes up to 12 Liter. Technical Data
Adjustable/Fixed Thermostat. Light Housing. Assembled with a built-in thermostat and 1.3 mtr. power cord. Coolant Volumes up to 12 Liter. Technical Data
Part Number: VT6-101 Engine Model: TD60, TD61, TD70, TD71, TD100, TD101, VE10, TD120, TD121 120 V Watts: 1000 Application Information: Mounts into threaded opening on eft side of engine. Heat Shield Required: No Technical Data
FW Murphy Liquid level switch EL150K1 The L150 Series Level Swichgage® instrument is a combination liquid level gage and low-limit switch; each unit includes: (1) a chamber with pivotal float (2) an indicating dial with pointer (3) a low-level contact. When properly installed and maintained, the float operates the pointer which, in turn, both indicates level during normal operation and closes a switching circuit if the level falls to the low-limit set point. Technical Data
FW Murphy Liquid Level Switch EL150EX. The EL150EX Liquid Level Switch® instrument is an explosion-proof combination liquid level gauge and low level switch. The instrument includes: (1) a chamber with a rotating float, (2) a dial with pointer, and (3) a low level contact. When properly installed and maintained, the float operates the pointer which in turn both indicates the level during normal operation and closes a switching circuit when the level drops to the low limit set point. The EL150EX has a fixed set point. When properly installed, the unit mounts at your desired liquid level. The set point cannot be tampered with. The primary use of the EL150EX is for engine cooling systems, peak or expansion tanks, condenser radiator or vapor phase systems, pressurized or atmospheric systems. The EL150EX Liquid Level Swichgage® instrument can also be used to monitor lubricating oil, hydraulic fluid, or diesel fuel reservoirs and to activate and/or deactivate alarms at a predetermined minimum level. This instrument is designed for low pressure systems with a maximum of 25 psi (172 kPa) [1.72 bar]. Snap-in Switch: SPDT rated 10A @ 125 VAC; 0.5A @ 125VDC; 10A 30VDC. Sand cast aluminum housing, painted body; 304 stainless steel float; tempered glass lens. Wires to terminal block. CSA certified for Class I, Division I, Groups C…
The L129 Series Lube Level Swichgage is a combined lube level indicator and adjustable limit switch for low and high levels. It protects against low oil levels or excessive levels from overfilling, fuel leakage, or water seepage into the crankcase. - Check lube levels without shutdown - Suitable for engines, pumps, and compressors - Combination indicator gauge with high and low limit switch - Float-operated Technical Data
Murphy L129CK1 Level Switch The L129 Series Lube Level Swichgage® instrument is a combination lube level indicating gage and adjustable low and high limit switches. It provides protection against low oil level or high level caused by overfill or fuel or water seepage into the crankcase. The L129CK1 was designed for applications requiring a three-wire, above ground electrical circuit. It features ungrounded contacts and a conduit hub to protect electrical wiring. Options are available for both models. Check Lube Level Without Shutting Down. Use On Engines, Pumps, And Compressors. Technical Data
The LM300 Level Maintainer automatically adds oil to the crankcase as needed to keep the lube level normal. LM300 base model comes as a level maintainer only (no switches). Technical Data
The DF series are diaphragm-operated hydrostatic head pressure level switches. A pressure sensitive diaphragm operates a snap-switch that can be wired directly to electric pilot circuits to control pumps at predetermined levels. Typical application is to start and stop electric driven pump(s) to maintain tank levels. It is also applicable to engine-driven pumps.DF755 is suitable for atmospheric tanks in a non-hazardous area. The SPDT snap-switch for the DF755 is preset for a 4 in. (102 mm) differential in liquid level. Technical Data
The Murphy Bilge Level Switch BLS1 is constructed of materials not affected by marine atmospheres; Aluminum or Bronze body and cover, Buna-N diaphragm. NOTE: A pilot relay may be used for higher contact ratings (see Typical Wiring Diagram).Features: Operates Bilge Pumps or Alarms Remote Switch and Moving Parts Kept Unaffected by Corrosion Aluminum Body and Cover Technical Data
Designed for harsh gas compressor scrubber applications, the LS200 Liquid Level Switches feature a robust design that trips on rising liquid level only. With both electric and pneumatic models available, the instruments screw directly into the vessel or can be mounted via an external float chamber. The nickel-plated body provides enhanced corrosion protection while the 304 stainless steel float operates in 0.55 specific gravity and heavier fluids. Additional features include: Rated for 2000 psi (13.8 MPa) [138 bar] working pressure Listed for Class I, Div. 1, Grp. C & D locations Canadian registered Stainless steel models available for corrosive atmospheres The LS200 Series replaces the FW Murphy Series L1200 Liquid Level Switches. The MSLS (Scrubber Level System) replaces the LS200 high-level shut-down switch with the MLS-020 magnetic level switch. Technical Data
The FW Murphy LM500 model maintains the crankcase oil level of an engine, pump or compressor. Adjusted to the correct running oil level, the LM500 will replenish oil as it is used. The low level switch will alarm and/or shut down the equipment if the supply oil is lost and the equipment continues to use oil. Direct Mount (DM) capable Eliminates under/overfill due to “human error” See oil level and condition without shutting down Simple installation Automatically maintains lube level Low level, 3-wire, snap-action switch Positive sealing Thumb-Valve™
Part Number: VT6-101 Engine Model: TD60, TD61, TD70, TD71, TD100, TD101, VE10, TD120, TD121 240 V Watts: 1000 Application Information: Mounts into threaded opening on eft side of engine. Heat Shield Required: No Technical Data
Part Number: PF121-002 Engine Model: D12C After Serial #250502 120 V Watts: 1250 Application Information: Replaces oval shaped plate on right side of engine. Heat Shield Required: Yes Technical Data
Part Number: PF151-005 Engine Model: D12C After Serial #250502 120 V Watts: 1500 Application Information: Replaces oval shaped plate on right side of engine. Heat Shield Required: Yes Technical Data
Part Number: PF151-007 Engine Model: D9 120 V Watts: 1500 Application Information: Replaces oval shaped plate on right side of engine. Heat Shield Required: No Technical Data
Part Number: PF122-002 Engine Model: D12C After Serial #250502 240 V Watts: 1250 Application Information: Replaces oval shaped plate on right side of engine. Heat Shield Required: Yes Technical Data
Part Number: PF152-005 Engine Model: D12C After Serial #250502 240 V Watts: 1500 Application Information: Replaces oval shaped plate on right side of engine. Heat Shield Required: Yes Technical Data
Part Number: PF152-007 without cord Engine Model: D9 Voltage:240 V Watts: 1500 Application Information: Replaces oval shaped plate on right side of engine. Heat Shield Required: No
Part Number: PF122-003 Engine Model: D2840, D2842, D2848 240 V Watts: 1250 Application Information: Replace oval shaped plate in lower water pipe on right side of engine. Heat Shield Required: No
Part Number: PF152-006 Engine Model: D2866, D2876 240 V Watts: 1500 Application Information: Replace 3 bolt plate on left side of engine. May require adapter if 3 bolt opening is not available on engine. Consult customer service. Heat Shield Required: No
The LM500-TF model includes a test feature that confirms both the float and switch are operating correctly with a single press of the test button. Direct Mount (DM) capable Eliminates under/overfill due to “human error” See oil level and condition without shutting down Simple installation Automatically maintains lube level Low level, 3-wire, snap-action switch Positive sealing Thumb-Valve™ The LM500-TF model includes a test feature that confirms both the float and switch are operating correctly with a single press of the test button. Direct Mount (DM) capable Eliminates under/overfill due to “human error” See oil level and condition without shutting down Simple installation Automatically maintains lube level Low level, 3-wire, snap-action switch Positive sealing Thumb-Valve™
24V, 7W, PSI:VAC, Hz DC We supply original high-quality PeterPaul solenoid valves with a wide variety of sizes and a range of control options over the flow of liquids and gases suited for all industrial and medical applications. See additional information below for specifications. You can contact us as well for consultation and request a quote.
12V, Hz:DC, Watts: 9.5, PSI:5000 Hz:DC, Watts:9.5, PSI:5000 We supply original high-quality PeterPaul solenoid valves with a wide variety of sizes and a range of control options over the flow of liquids and gases suited for all industrial and medical applications. See additional information below for specifications. You can contact us as well for consultation and request a quote.
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Cookie settingsACCEPT
Privacy & Cookies Policy
Privacy Overview
This website uses cookies to improve your experience while you navigate through the website. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience. To read more about cookies we use, please go to Cookie Policy page
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.